1001 NW Technology Drive, Lee's Summit, MO 64086 // (800) 305-5198 // (816) 347-0143 Fax // info@viracoribt.com BasoFunction HRT Tetracycline
TEST CODE: 501358
CPT CODE:86352 (x1)
Clinical Utility
The BasoFunction test may be useful with patients who have a suggestive history of adverse reactions to the indicated allergen and for whom skin testing is not appropriate or available. Procedure
Cell Setup: Peripheral blood leukocytes are enriched from heparinized whole blood and stimulated with fMLP Basophil Activation Test, allergen (BasoFunction Test) or buffer alone. Following a brief culture the supernatant containing secreted histamine is separated from the cells. Histamine Test: A validated histamine ELISA quantifies histamine that was secreted by any stimulated control. Viracor-IBT Laboratories determined the performance characteristics of this test. This test has not been cleared or approved for diagnostic use by the Assay Range
The reference range varies for each allergen Causes For Rejection
Hemolyzed, frozen or refrigerated blood is not acceptable and will be rejected for testing. Do Not use Lithium Heparin tubes Turnaround Time
Setup Schedule: Basophil Activation M-F, ELISA portion: Mon, Tues, Thurs. TAT: 3-4 Business days from receipt of specimen Shipping
Ship OVERNIGHT. Samples are received Monday thru Friday ONLY. Specimen MUST BE received within 48 hours of draw. Specimen Information
whole blood - 8-10 mL (for 5 antigens) Sodium heparin tube. Keep blood at room temperature at all times. Specimen must arrive within
48 hours of draw. Samples are to be shipped by overnight delivery. Samples are received Monday through Friday. Patients taking
calcineurin inhibitors should stop their medication 72 hours prior to draw. Patients taking prednisone should stop medication for 2 weeks
prior to draw
Stability
Disclaimer
1001 NW Technology Drive, Lee's Summit, MO 64086 // (800) 305-5198 // (816) 347-0143 Fax // info@viracoribt.com Specimens are approved for testing in New York only when indicated in the Specimen Information field above. The CPT codes provided are based on Viracor-IBT's interpretation of the American Medical Association's Current Procedural Terminology (CPT) codes and are provided for general informational purposes only. CPT coding is the sole responsibility of the billing party. Questions regarding coding should be addressed to your local Medicare carrier. Viracor-IBT assumes no responsibility for billing errors due to reliance on the CPT codes illustrated in this material. REFERENCES
Gruchalla, R S. J Allergy Clin Immunol 2001, 108 (4):475-488. Winther, L et al. Allergy 1999, 54: 436-445. Zia, P. K. et al. Clinical Chemistry 1998, 44: 2063-2065. Sainte-Laudy, J et al. Inflammation Research 1998, 47: 401-8.

Source: http://www.viracoribt.com/Resource_/TestDetailPdf/BasoFunction-HRT-Tetracycline-501358.pdf

Microsoft word - albs.doc

Atomic Lithium Beam Spectroscopy for N and T in Reactive Plasmas Institut für Experimentalphysik II, Ruhr-Universität Bochum, D-44780 Bochum, Germany 1. Introduction In a reactive plasma the species composition and the flows of particles to a substrate depend upon the electron energy distribution and its spatial variation and time dependence. The electron density has a large influence on

Chemwatch australian msds 4833-73

RAMSET CHEMSET MAXIMA SPIN CAPSULES Chemwatch Independent Material Safety Data Sheet Issue Date: 24-Jan-2011 CHEMWATCH 4833-73 Version No:6 CD 2010/4 Page 1 of 8 Section 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME RAMSET CHEMSET MAXIMA SPIN CAPSULES SYNONYMS "Product Code: CHEM08, CHEM10, CHEM12, ", CHEM16 PROPER SHIPPING NAME POLYESTER

Copyright © 2010-2014 Internet pdf articles